CiteScore: 1.9     h-index: 21

Analysis and detection of incident light attenuation with a continuous flow injection by using the precipitating reaction of fluconazole and phosphomolybidic acid by NAG4SX3-3D instrument
Analysis and detection of incident light attenuation with a continuous flow injection by using the precipitating reaction of fluconazole and phosphomolybidic acid by NAG4SX3-3D instrument

Nagham Shakir Turkie; Sarah Faris Hameed

Volume 6, Issue 3 , July 2022, , Pages 255-272

https://doi.org/10.22034/ajgc.2022.3.6

Abstract
  A quick and sensitive approach for detecting fluconazole by formation a pale yellow precipitate from the interaction of phosphomolybdic acid and fluconazole in a sulfuric acid medium. ...  Read More
Continuous flow injection analysis via NAG-4SX3-3D analyzer utilized to determination of resorcinol
Continuous flow injection analysis via NAG-4SX3-3D analyzer utilized to determination of resorcinol

Nagham Shakir Turkie; Sarah Faris Hameed

Volume 6, Issue 2 , April 2022, , Pages 129-144

https://doi.org/10.22034/ajgc.2022.2.3

Abstract
  A fast and sensitive method for detecting resorcinol by producing yellowish-green color species using the reaction of potassium dichromate with resorcinol in a sulfuric acid medium. ...  Read More
Development of a new methodology for Lincomycin.HCI (LINO.HCI) determination using phosphomolybdic acid (PMA) as a reagent and ISNAG-Fluorimeter Instrument via CFIA
Development of a new methodology for Lincomycin.HCI (LINO.HCI) determination using phosphomolybdic acid (PMA) as a reagent and ISNAG-Fluorimeter Instrument via CFIA

Nagham Shakir.Turkie; Zahraa Naeem Abd Oun

Volume 6, Issue 1 , January 2022, , Pages 88-102

https://doi.org/10.22034/ajgc.2022.1.7

Abstract
  The reaction is based on the Lincomycin that has been responded. In an acidic solution, combine HCl and phosphomolybdic acid to produce a white color precipitate that may be measured ...  Read More
Promethazine-HCl determination via CFIA-NAG-ADF-300-2 instrument using phosphomolybdic acid as a precipitating reagent
Promethazine-HCl determination via CFIA-NAG-ADF-300-2 instrument using phosphomolybdic acid as a precipitating reagent

Nagham S. Turkey; Ghadah Fadhel

Volume 5, Issue 4 , October 2021, , Pages 387-403

https://doi.org/10.22034/ajgc.2021.314786.1320

Abstract
  In this work, a highly accurate and sensitive method with low cost analyzer NAG/ADF/(300-2) homemade instrument coupled under continuous flow injection (CFIA) analysis was used to determine  ...  Read More